Alliance Laundry Systems D715I User Manual

Page of 34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
19
510963
3. Use the three screws from the envelope located in 
the cylinder to attach the power cord wires to the 
terminal block.
Figure 17 
4. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws 
firmly may result in wire failure at the terminal 
block.
5. Secure the strain relief to the power cord, or 
wires, where they enter the dryer cabinet.
6. Check the continuity of the ground connection 
before plugging the cord into an outlet. Use an 
acceptable indicating device connected to the 
center grounding pin of the plug and the green 
screw on the back of the cabinet.
7. Reinstall access cover and screw.
Four-Wire Plug
Figure 18 
1. Remove access cover from rear of dryer.
Figure 19 
D286I
1
“L1” Terminal
2
Neutral Terminal
3
“L2” Terminal
1
2
3
D815I
1
Typical Four-Wire Receptacle
2
Power Cord – Not Supplied with Dryer 
(Four-Wire)
3
Strain Relief Nut
4
Strain Relief
D695I
1
2
3
4