Installation
19
512686
Gas Dryers
(120 Volt, 60 Hertz, With 3-Prong Grounding 
Plug)
NOTE:  The wiring diagram is located behind the 
control panel, inside the control cabinet.
• Each dryer is designed to be operated on a 
separate branch, polarized, three-wire, effectively 
grounded, 120 Volt, 60 Hertz, AC (alternating 
current) circuit protected by a 20 Ampere fuse
equivalent fusetron or circuit breaker.
• The three-prong grounding plug on the power 
cord should be plugged directly into a polarized 
three-slot effectively grounded receptacle rated 
120 Volts AC (alternating current) 20 Amps. 
Refer to Figure 21 to determine correct polarity 
of the wall receptacle.
Figure 21 
NOTE: A qualified electrician should check the 
polarity of the wall receptacles. If a voltage reading 
is measured other than that illustrated, the 
qualified electrician should correct the problem.
• DO NOT OPERATE OTHER APPLIANCES 
ON THE SAME CIRCUIT WHEN THIS 
APPLIANCE IS OPERATING. DO NOT 
.
Figure 22 
To reduce the risk of fire, electric shock or 
personal injury, all wiring and grounding 
to the dryer unit MUST conform with the 
local codes, or in the absence of local 
codes, with the latest edition of the 
National Electrical Code ANSI/NFPA 70 or 
the Canadian Electrical Code, CSA C22.1, 
and such local regulations as might 
apply. It is the customer’s responsibility 
to have the wiring and fuses checked by a 
qualified electrician to make sure the 
laundry room has adequate electrical 
power to operate the dryer unit.
W084
WARNING
This dryer is equipped with a three-prong 
(grounding) plug for your protection 
against shock hazard and should be 
plugged directly into a properly grounded 
three-prong receptacle. Do not cut or 
remove the grounding prong from this 
plug.
W036
WARNING
D739I
1
L1
2
Ground
3
Neutral
4
Round Grounding Prong
5
Neutral Side
D009I
D739I
1
2
3
4
5
STANDARD 120 VOLT, 60 HERTZ, 
3-WIRE EFFECTIVELY GROUNDED CIRCUIT
 115 ± 12 
V.A.C.
 115 ± 12 
V.A.C.
 0 
V.A.C.
DO NOT 
OVERLOAD 
CIRCUITS
To reduce the risk of an electric shock or 
fire, DO NOT use an extension cord or an 
adapter to connect the dryer unit to the 
electrical power source.
W152
WARNING