Maintenance instruction of the machine
 Clean the entire cabinet of the machine regularly and remove all traces of soap, 
etc....
 Remove all detergent residue in the soap dispenser with hot water.
 Clean the door gasket and remove all detergents and other products.
 Shut off the main water, steam, and power connections at the end of each day.  
Do not change the setting of the water inlet taps on boiler fed machines once 
these have been installed.
 It is recommended to leave the door and soap dispenser open after use, to 
ventilate the machine.
 Check for proper door lock operation on a daily basis.
General maintenance
 
Clean AC drive filter:
  a. Snap off external plastic cover which contains filter.
  b. Remove foam filter from cover.
  c. Wash filter with warm water and allow to air dry. Filter can be vacuumed clean. 
End of day
WARNING
To reduce the risk of electric shock, disconnect this appliance 
from the power supply before attempting any user maintenance. 
Turning the controls to the OFF position does not disconnect this 
appliance from the power supply.
Before starting wiring or inspection, power must be switched OFF, 
check to make sure that the operation panel indicator is off.  
Any person who is involved in wiring or inspection shall wait for 
at least 10 minutes after the power supply has been switched OFF 
and check that there is no residual voltage using a tester or the 
like. The capacitor of the inverter or the EMC filter is charged with 
a high voltage for some time after power OFF, and it is dangerous.
 Two to three months after the first use, the V-belts of the motors should be 
checked whether they still have the correct tension. This is necessary because 
these belts are subject to a one-time stretching when first used. If this is not 
done, the belt starts to slip after a few months and will break shortly afterwards.
 Check the water inlet filters to make sure they are not blocked by calcification.
 Check the drain valve for obstructions.
 
If a machine frequently skips the final spin, check whether the probe of the out of 
balance switch is still in the appropriate position, that is horizontally centered and 
vertically 1/3 from the bottom inside the window. (When the drum is empty).
Periodical maintenance