Alliance Laundry Systems hc165 User Manual

Page of 56
7
A
B
51
Important
- Clean the drainpipe every 6 months in case drain (B) is used.
- The water still being in the drain needs to be drained using drain (A) before 
  cleaning the drainpipe or replacing the exhaust valve.
 Verify that the belts are running in the middle of the basket pulley.
 Verify the belt tension according to the table below. Belt tension measurements 
should be taken as close as possible to the center of the belt span (see figure).
Annual maintenance
Belt tension:
Belt tension testing table
Model
Belt
Frequency (Hz)
Tension force (N)
Deflection (mm)
Deflection force
 
MIN
 
MAX
 
MIN
 
MAX
at MIN  
tension
at MAX 
tension
 
MAX
HC60
8PJ 1355
107
137
470
766
7
4
40
HC65
8PJ 1355
107
137
470
766
7
4
40
HC75
8PJ 1355
107
137
470
766
7
4
40
HC100
8PJ 1355
107
137
470
766
7
4
40
HC135
10J 1473
75
105
316
618
10,5
6,4
40
HC165
10J 1473
75
105
316
618
10,5
6,4
40
1  Deflection
2  Span length