Alliance Laundry Systems nx30bvxm7 User Manual

Page of 20
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
11
9002062
Installation
Dimensional Clearances
Table 1 shows recommended minimum clearances on 
all sides of the washer-extractor.
Machine Foundation
Thoroughness of detail must be stressed with all 
foundation work to ensure a stable unit installation, 
eliminating possibilities of excessive vibration during 
extract.
The washer-extractor must be placed on a smooth level 
surface so that the entire base of the machine is 
supported and rests on the mounting surface.
The standard installation does not require anchoring 
unless mandated by state or local codes.
Kinetic energy of the cylinder and dynamic loads on 
the floor or foundation are shown in Table 2.
Table 2 can be used as a reference when designing 
floors and foundations.
Recommended Minimum Clearances
Model
18
30
Minimum rear clearance
600 mm 
(24 in.)
600 mm 
(24 in.)
Minimum clearance 
between machine and wall
150 mm 
(6 in.)
150 mm 
(6 in.)
Minimum clearance 
between machines (side)
25.4 mm 
(1 in.)
25.4 mm 
(1 in.)
Minimum front clearance
(door swing)
419 mm 
(16.5 in.)
419 mm 
(16.5 in.)
Table 1 
Floor Load Data
Model
18
30
Kinetic energy of the 
cylinder
1386 N/m
2592 N/m
Dynamic bottom load
700 N/16 Hz
1000 N/16 Hz
Table 2 
Ensure that the machine is installed on a 
level floor of sufficient strength and that 
the recommended clearances for 
inspection and maintenance are provided. 
Never allow the inspection and 
maintenance space to be blocked.
W488
CAUTION