heatcraft-refrigeration-p h-im-77d User Manual

Page of 16
11
  Standard or 
 
 
 
 
  Connections (In.)   
Approx.
 Reverse Flow 
              Dimensions (In.) 
 
Coil 
 
 
Shipping
 
Models 
Inlet 
Suction  Drain 
Wt. (Lbs.)
 
17 
/
4
 
16 
7
/
8
 
12 
1
/
4
 
15 
5
/
8
 
/
8
 OD 
/
8
 OD 
5
/
8
 OD 
19
 
17 
19 
/
4
 
16 
7
/
8
 
14 
1
/
4
 
15 
5
/
8
 
/
8
 OD 
/
8
 OD 
5
/
8
 OD 
20
 
19 
/
4
 
1
/
4
 
14 
1
/
4
 
22 
/
8
 OD 
1
/
2
 OD 
5
/
8
 OD 
28
Mounting
The. standard. flow. mullion. unit. draws. air. in. at. the. top. and.
discharges.out.the.bottom..The.reverse.flow.mullion.draws.air.
in.at.the.bottom.and.discharges.out.the.top...The.unit.may.be.
mounted.in.a.mullion.or.against.a.back.or.side.wall.
When.mounting.to.the.mullion.of.under.counter.refrigerators,.
mounting.holes.are.located.on.both.ends.of.the.unit.for.attaching.
to.“customer.furnished”.mounting.brackets.
When.wall.mounted,.four.“L”.type.brackets.and.eight.stainless.
steel.sheet.metal.screws.are.provided.to.attach.the.brackets.to.
side.panels.
   
  IMPORTANT:  A minimum of 2 inches must be provided
     between the top of the unit and the top of the cabinet.
Standard & Reverse Air Flow Wall Mullion Unit Cooler
Dimensional Data
 
 
  25°F Sat. Suction Temp.   
  20°F Sat. Suction Temp.
 
Model 
BTUH @                          R-22 
 
BTUH @                          R-22 
 
 
Size 
10°F TD 
Alco 
Sporlan 
15°F TD 
Alco 
Sporlan 
 
100 
 
 
1950 
 
 
 
17 
1700 
HFS-1/4HC 
EFV-1/5C 
2550 
HFS-1/4HC 
 
 
200 
 
 
450 
 
Expansion Valve Recommendations
 
Part 
Standard 
Reverse
  Description 
Down Flow 
Up Flow
 
115V Motor 
2500701 
2500701
  208/20V Motor 
2500801 
2500801
 
Fan Blade 
5102C 
5117C
 Fan Guard (1-17)  
5076E 
5076E
  Fan Guard (2) 
5077E 
5077E
  Motor Mount 
91179001 
91179001
 Drain Pan (1-17) 
74422002 
74422002
  Drain Pan (2) 
7446002 
7446002
FOR FOOD 
SERVICE 
INSTALLATIONS
. . .  seal any joint 
between unit cooler and 
cooler liner with a sealant 
listed by the National 
Sanitation Foundation, 
Standard 51
A.top.barrier.is.supplied.and.must.be.used.if.combustible.material..
is.above.the.unit..On.reverse.flow.models.the.barrier.may.be.used.
to.direct.the.air.straight.out.or.up.at.a.45°.angle..Holes.and.slots.
are.provided.to.adjust.the.barrier..If.noncombustible.material.is.
used.above.the.unit,.the.barrier.may.be.discarded.if.desired.
Knockouts.are.provided.for.bringing.the.refrigerant.piping.through.
either.end.of.the.cabinet..An.electrical.knockout.is.provided.into.
an.internal.junction.box.
Dimensional Diagram
NOMENCLATURE
XXX  K  13  A  G
KM = Standard 
Vintage
           Air Flow
RAM=Reverse
           Air Flow 
A = 115-1-60
    K = Coated Coil 
B = 208/20-1-60
                     Size 
                      
EFV-1/C
EFV-1/5C
Replacement Parts
Commercial Refrigeration Parts