PROGRAMMING THE BREWER (cont.)
Procedure to test components (outputs):
1.  Place  brew  funnels  into  rails  on  both  sides  of 
brewer.
2.  Place a server beneath each brew funnel.
3.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to press and release switch until SERVICE TOOLS 
appears.
4.  Press YES to run tests on various components 
and outputs within the brewer. Pressing NO will 
exit this function and advance to the next function 
screen.
5.  The display should read TEST OUTPUTS.
6.  Press and release YES. The display should read 
LEFT BREW VALVE.
7.  To test LEFT BREW VALVE, press ON. If the brew 
valve is functional, water should run from the left 
brew side.
8.  Press OFF to end flow of water.
9.  Press NEXT to advance to the next component to 
be tested.
FUNNEL DETECT (optional)
 
This function allows the operator to prevent the 
start of a brew cycle if a Smart Funnel is not positioned 
correctly in the funnel rails.
Procedure to set funnel detect:
1.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to  press  and  release  switch  until  display  reads 
FUNNEL DETECT.
2.  NO or YES should be flashing to indicate the cur-
rent setting.
4.  Select YES to prevent brewing if a Smart Funnel is 
not correctly situated in the rails.  If this function 
is activated and a brew cycle is attempted with the 
funnel not properly situated, the display will read,  
FUNNEL NOT IN PLACE, until one is in place.
5.  Select NO to allow brewing without a Smart Fun-
nel in place. This is selected when brewing with a 
funnel other than a Smart Funnel (a regular brew 
funnel).
6.  When finished, press and release DONE. This will 
retain the changes, exit this function screen and 
advance to the next. Another alternative is to press 
the ON/OFF switch (either on DUAL brewers) lo-
cated on the front switch panel to exit the FUNNEL 
DETECT and return to the MAIN SCREEN.
FUNNEL DETECT ?
  NO 
DONE 
YES
SERVICE TOOLS
 
This function allows the testing of individual com-
ponents and the ability to check switches for proper 
function. This function also tests the Soft Heat server's 
status on the brewer (in place or removed), and the 
funnel  sensor  coil's  frequency  (diagnostic  tool  for 
troubleshooting purposes only).
Testing individual components (outputs):
 
This will allow the operator to test the operation 
of individual components and outputs of the brewer.  
The components that can be individually tested are as 
follows:
DUAL Brewers 
Left Brew Valve
Left Bypass Valve
Left Funnel Lock
Right Brew Valve
Right Bypass Valve
Right Funnel Lock
Refill Valve
Tank Heaters
Heater Contactor
SINGLE Brewers
Brew Valve
Bypass Valve
Funnel Lock (Optional)
Refill Valve
Tank Heaters
Heater Contactor