PROGRAMMING THE BREWER (cont.)
SERVICE TOOLS (cont.)
NOTE: 
To bypass testing any component, press NEXT 
to advance to the next one, without testing the previ-
ous component.
10. To  test  LEFT  BYPASS,  press  ON.  If  the  bypass 
valve is functional, water should run from the left 
brew bypass.
11. Press OFF to end flow of water.
12. Press NEXT to advance to the next component to 
be tested.
13. To test LEFT FUNNEL LOCK, press ON. If the fun-
nel lock is functional, the lock will come down to 
hold the funnel in place.
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to 
be tested.
16. Follow steps 7 through 15 to test the right side 
components.
17. To test REFILL VALVE, press ON. If the refill valve 
is functional, the sound of the valve operating will 
be heard.
18. Press OFF to end testing of refill valve.
19. Press NEXT to advance to the next component to 
be tested.
20. To test TANK HEATERS, connect a voltmeter across 
each of the tank heaters to check for voltage.
21. Press ON. The correct voltage should be present 
at the heater terminals.
22. Press OFF to end testing of the tank heaters.
NOTE: The tank heater will automatically turn off if 
left on too long.
23. After testing the tank heater, press NEXT to advance 
to the next test.
24. The HEATER CONTACTOR is used only on certain 
models. Check the machine schematic to see if the 
contactor is present. Connect a voltmeter across a 
tank heater that is operated by the contactor and 
press ON to check that correct voltage is present. 
Press OFF and confirm the voltage is zero.
25. Press NEXT to return to TEST OUTPUTS.
26. o exit SERVICE TOOLS, press and release the ON/
OFF switch (either on DUAL brewers) located on 
the front switch panel. This will return to the MAIN 
SCREEN.
Procedure to test switches:
 
This function allows the operator to test the opera-
tion of the individual switches on the front panel.
1.  Place brew funnel(s) into rails on the brewer (both 
sides on DUAL brewers).
2.  Place a server beneath each brew funnel.
3.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to press and release switch until SERVICE TOOLS 
appears.
4.  Press YES to run tests on various components 
and outputs within the brewer. (Pressing NO will 
exit this function and advance to the next function 
screen.) 
5.  The display should read TEST OUTPUTS.
6.  In TEST OUTPUTS screen, press NO.  This advances 
to TEST SWITCHES.
7.  Pressing  NO  in  this  screen  will  advance  to  the  
next function. Press YES in the TEST SWITCHES 
screen to test the switches. The display will read 
NOTHING PRESSED.
8.  From this screen, press any of the switches on the 
front of the brewer except the upper right hidden 
switch.  While the switch is pressed, the display 
shows the name of that switch.  If the name does 
not appear, or if it remains after the switch has been 
released, the switch is defective.  Each switch can 
be tested in this manner.
9.  After all switches have been tested, press and re-
lease the right hidden switch (®). This will return 
to TEST SWITCHES?. Press and release switch 
again  to  advance  to  TEST  SERVERS?.  Another 
alternative  is  to  press  and  release  the  ON/OFF 
switch (either on DUAL brewers) located on the 
front switch panel. This will exit TEST SWITCHES 
and return to the MAIN SCREEN.
Procedures to test coil frequency:
1.  Place brew funnel(s) into funnel rails of the brewer 
(both side on DUAL brewers).
2.  Place  a  ThermoFresh  server  beneath  brew 
funnel(s).
3.  Press  and  hold  the  upper  right  hidden  switch 
until the display reads UNITS. Release the switch. 
Continue pressing and releasing the upper right 
hidden switch until SERVICE TOOLS appears. 
4.  Pressing NO  will exit this function and advance to 