Honeywell T8011R User Manual

Page of 6
69-1436–1
4
T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT
Mounting Thermostat To Wallplate
1. Slide SYSTEM switch to the Off position.
2. Engage the tabs at the top of the thermostat and
wallplate.
3. Swing down the thermostat and press the lower
edge of the thermostat onto the wallplate to latch.
See Fig. 6.
Fig. 6. Mounting thermostat to wallplate.
INSTALLER SETUP
Setting 
°
F/
°
C Indication and Heat Cycle Rate
The following instructions provide the information neces-
sary to change the heating cycle rate to match the heating
equipment and to choose either Fahrenheit (
°
F) or Celsius
(
°
C) display.
NOTE:
All four steps must be completed to save
changes to the 
°
F/
°
C indication and the heat
cycle rate.
1. Enter Installer Setup.
a.
Use 
 or 
 keys
to set the tempera-
ture setpoint to 52
°
F (11
°
C).
b.
Press the 
 and
 keys simulta-
neously for more
than two seconds
to enter installer
setup.
c.
When released the three-digit software
revision code displayed.
d.
Press the 
 key.
Factory configura-
tion (FC) is
displayed
(A typical example
is shown, but
information displayed varies by model. This
information is for factory use only).
Optional System Checkout
When in steps 1c and 1d only, pressing the 
 key can be
used to turn heat or cool outputs on and off. Change the
SYSTEM switch setting to test heat or cool outputs. During
testing, the 5 minute minimum off time is bypassed. No
action takes place If the system switch is in the Off
position.
Examples: System setting at HEAT: If heat is on,
pressing the 
 key turns it off; if heat is off,
pressing the 
 key turns it on.
System setting at COOL: If cool is on,
pressing the 
 key turns it off; if cool is off,
pressing the 
 key turns it on.
NOTE:
In installer setup only, each press of the 
 key
momentarily displays 1. Each press of the 
 key
momentarily displays 2. When the keys are
released, these one-digit codes are no longer
displayed.
 2. Setting 
°
C or 
°
F.
a.
Press the 
 key
again to display
the current setting.
b.
Press the 
 key to
change the 
°
C or
°
F indication.
M14699
DASHED LINES INDICATE TABS
ON BACK OF THERMOSTAT
ENGAGE TABS  AT TOP  OF THERMOSTAT
WITH SLOTS ON MOUNTING PLATE.
PRESS LOWER EDGE OF 
CASE TO  LATCH.
A
B
SYSTEM
Cool  Off  Heat  Em Ht 
Auto  On
FAN
Hold
Select
SYSTEM
Cool  O
ff  H
eat  E
m Ht
Auto  On
FAN
Hold
Select
EM. HT
. AUX. HT
.
PM
M12582A
SET
HT.
M12583A
M12584A
M12586A
M12587A