Honeywell T8011R User Manual

Page of 6
69-1436–1
5
T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT
3. Setting Heat Cycle Rate (see Table 2 for cycle rate
options and equipment).
a.
Press the 
 key to
display the current
heat cycle rate
setting of 3, 4, 5,
6, 9 or 12 cph.
b.
If the desired cycle
rate is displayed,
press the 
 key to
exit the installer
setup.
c.
To change the
heat cycle rate,
press the 
 key until your choice of 3, 4, 5, 6,
9 or 12 is displayed.
d.
Press the 
 key to
display cooling
algorithm configu-
ration default.
e.
Press the 
 key
again to change
cooling algorithm to C1 or C3.
C1 = Standard cooling algorithm.
C3 = Agressive cooling algorithm (can
cause overshooting).
f.
Press the 
 key again. Current configuration
(CC) is displayed. A typical example is shown,
but CC varies by
model. (This
information is for
factory use only.)
4. Exit Installer Setup.
a.
Press
the 
key to
save all
changes
and
return to
normal
operation.
Table 2. Heating Cycle Rate
NOTE:
Stage one heat and cool cycle rates are fixed at
3 cph. Only stage two heat cycle rates are
selectable.
OPERATION
Setting FAN and SYSTEM Switches
Fan and system settings are controlled manually by using
the switches located at the bottom of the
thermostat case. See Fig. 7.
FAN Switch
Fan switch settings are:
On: The fan runs continuously. Use for improved air
circulation and air quality.
Auto: Normal setting for most homes. The fan starts
and stops with the equipment.
Slide the FAN switch in the lower left corner of the
thermostat to select the desired fan setting.
SYSTEM Switch
System switch settings control thermostat operation as
follows:
Cool: The thermostat controls the cooling system.
Off: Both heating and cooling are off.
Heat: The thermostat controls the heating system.
Em. Ht.: The thermostat cycles auxiliary heat (W2) and
emergency heat relay (E) as needed to maintain
setpoint. Terminal L is energized continuously (fault
heat relay is on continuously). Cooling system is off.
Compressor is de-energized.
Slide the SYSTEM switch in the lower right corner of the
thermostat to select the desired system setting.
Fig. 7. Digital Display and System Switches.
SYSTEM
Cool  Off  Heat Em Ht
Auto  On
FAN
T8011
M14700
Hold
Select
PM
M12590A
PM
M14691
M14692
M12589A
M12588A
System
Cycles Per Hour
Hydronic Heat, Condensing  
Gas Furnaces
a
3
Gas or Oil Forced Air
6
Electric Heat
9
Special Applications
b
4, 5, 12
a
High efficiency furnace (90+).
b
Refer to the equipment manufacturer’s Instructions.