KitchenAid KFRS365TSS User Manual

Page of 60
8
On freestanding models, the model/serial number rating plate is 
located inside the grill cabinet on the right-hand cabinet side. 
See the following illustration.
On built-in models, the model/serial number rating plate is 
located on the right-hand side of the grill. See the following 
illustration.
Recommended Ground Method
The outdoor grill, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code ANSI/NFPA 70, or Canadian 
Electrical Code, CSA C22.1.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest 
edition.
IMPORTANT: Grill must be connected to a regulated gas supply.
Refer to the model/serial rating plate for information on the type
of gas that can be used. If this information does not agree with
the type of gas available, check with your local gas supplier.
Gas Conversion:
No attempt shall be made to convert the grill from the gas
specified on the model/serial rating plate for use with a different
gas type without consulting the serving gas supplier. The
conversion kits specified must be used.
Gas Pressure Regulator
The gas pressure regulator supplied with this grill must be used. 
The inlet (supply) pressure to the regulator should be as follows 
for proper operation:
LP Gas:
Operating pressure: 11" (27.9 cm) WCP
Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP
Natural Gas:
Operating pressure: 4" (10.2 cm) WCP
Inlet (supply) pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP
maximum.
Contact local gas supplier if you are not sure about the inlet 
(supply) pressure.
A. Model/serial number plate
A. Model/serial number plate
A. 3-prong ground plug
B. 3-prong polarized type outdoor outlet
C. Ground prong
A
A
A
B
C
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” 
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 11” (28 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.