KitchenAid KFRS365TSS User Manual

Page of 60
9
Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for 
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a 
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice 
conversion is required. See “Assistance or Service” section to 
order.
Gas Supply Line Pressure Testing
Testing above ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):
The grill and its individual shutoff valve must be disconnected 
from the gas supply piping system during any pressure testing of 
that system at test pressures greater than ½ psig (3.5 kPa).
Testing below ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge) or 
lower:
The grill must be isolated from the gas supply piping system by 
closing its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pressures equal to 
or less than ½ psig (3.5 kPa).
Gas Connection Requirements
Style 1 - Freestanding Outdoor Grills
LP Gas Fuel Tank
This grill is equipped for use with a 20 lb LP gas fuel tank (fuel 
tank not supplied). A gas pressure regulator/hose assembly is 
supplied.
It is also design-certified by CSA International for local LP gas 
supply or for Natural gas with appropriate conversion.
The 20 lb LP gas fuel tank must be mounted and secured.
1. Open cabinet doors.
2. Press the locking tab on the tank tray and pull out the tray.
3. Place the 20 lb LP gas fuel tank bottom collar into the 
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the 
20 lb LP gas fuel tank to secure.
5. Slide tank tray back into the cabinet and lock into place.
Local LP Gas Supply
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified 
LP gas technician shall provide the LP gas supply to the selected 
grill location in accordance with the National Fuel Gas Code, 
ANSI Z223.1/NFPA 54 and local codes.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The 
qualified Natural gas technician shall provide the Natural gas 
supply to the selected grill location in accordance with the 
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, 
and local codes. For conversion to Natural gas, the Natural gas 
conversion kit must be used.
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
A. Gas pressure regulator/hose assembly
A. Tank tray locking tab
A
A
A. Locking screw
B. Mounting hole
C. Bottom collar
A. Grill gas pipe
B. New ANSI Z21.54 certified gray hose 
C. Rear of grill
D. To local LP gas supply
A
B
C
A
B
C
D