U-Line BI2015 User Manual

Page of 17
BI2015 — Ice Maker
www.U-LineService.com
6
02/2005
4. Remove the two door closer inserts from the existing 
bottom hinge and install as shown on the new bottom 
hinge (see Figure 8).
5. Remove existing bottom hinge (3 screws) and remount 
on opposite side TOP. Remove hinge screw pin.
6. Remove the plastic hole plug from the top of the door 
to allow the pivot pin to be inserted in the new 
location. Install the plug into the vacated hole on the 
opposite side.
7. With bottom of door facing up, remove pivot plate 
(2 screws), flip over, and remount on opposite side of 
door (see Figure 9). Be sure notch in plate faces center.
8. Holding door upright with top of door tilted forward, 
place hole of door pivot plate on bottom hinge screw 
pin (see Figure 10).
9. Tilt top of door into 
position in top hinge and 
install top hinge screw pin.
10. Install plastic screw plugs 
removed in Step 2 in old 
hinge holes (3 each, top 
and bottom).
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A circuit (normal household current). See 
Electrical Specifications on Page 14.
Water Supply
The unit requires a 1/4-inch OD water supply line and a 
shut-off valve. For more information see Page 13.
Environmental Requirements
The surrounding air temperature must be at least 50°F 
(10°C) but must not exceed 110°F (40°C). High ambient 
temperature ranges and warmer water supply will cause 
reduced ice production. Black and White units may be 
installed outdoors in a covered area. Stainless Steel BI2015 
units are deemed suitable for outdoor use by UL. The unit 
must not be located near heat-generating equipment or 
in direct sunlight.
Figure 7
Figure 8
Hinge
Screw
Pin
Door
Closer
Inserts
Figure 9
Figure 10