Cissell cissiman38 User Manual

Page of 36
Page 18
Page 18
Page 18
Page 18
Page 18
CA
CA
CA
CA
CAUSE
USE
USE
USE
USE
1A Steam Supply Valve “OFF”
1B Electric power”OFF”
2A Start switch not released by
cam when control knob is
pushed
2B Loose wires
2C Incorrect voltage of electrical
parts
2D Defective start switch
2E Defective solenoid
2F Defective solenoid linkage
3A Solenoid linkage adjusted
incorrectly
3B Loose valve seat
3C Worn valve
4A Trap not operating
4B Trap installed incorrectly
4C Check valve installed wrong or
sticking
REMEDY
REMEDY
REMEDY
REMEDY
REMEDY
Open valve in steam supply line.
Inspect electric service for blown
fuses, loose conections.  Turn main
disconnect “on”.
Align switch with centerline of
cam.  Adjust switch away from
cam with adjusting nuts.  Replace
panel, test and repeat if necessary.
Inspect and replace any loose
wires.
Inspect nameplate voltage and
voltage on electrical parts,
especially the solenoid.  Replace
switch if necessary.
Check switch to see that it
operates and will carry current.
Replace switch if necessary.
Inspect solenoid.  Replace if
necessary.
Check linkage between solenoid
and steam valve for broken or
loose parts.  Repair or replace as
required.  (See adjustment
instructions)
Inspect linkage and adjust
according to instructions.  Tighten
all lock nuts and set screws.
Inspect and tighten seat if
required.
Inspect valve parts.  Replace worn
parts as required.
Check size and operation of trap.
Repair or replace if required.
Check to see that direction of flow
in trap is correct and that trap is
correct and that trap is in or below
machine return line.
Check to see that direction of flow
is correct and valve not sticking.
SERVICE CHART
SERVICE CHART
SERVICE CHART
SERVICE CHART
SERVICE CHART
PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
(1) No Steam
(2) Blower motor will start, steam
won’t start
(3) Leaking steam valve
(4) Wet steam