Cissell cissiman38 User Manual

Page of 36
Page 20
Page 20
Page 20
Page 20
Page 20
CA
CA
CA
CA
CAUSE
USE
USE
USE
USE
7B Incorrect supply voltage
7C Air switch not being operated
by cam lever
7D Defective air switch
7E Defective Automatic relay
7F Air timer set at 0 time
7G Defective blower relay
7H Defective blower motor
7I
Loose wires
8
Defective start switch
9A Steam timer set at 0 time
9B Defective steam timer
9C Defective steam relay
REMEDY
REMEDY
REMEDY
REMEDY
REMEDY
Check power source.  Voltage
phase and frequency must be the
same as specified on machine
nameplate.
Check lever and cam plate.
Replace either if required.
Check switch to see if it operates
and will carry current.  Replace
switch if necessary.
Operating air switch should cause
automatic relay to operate.  If
defective, replace relay.
Timer knob may slip on the shaft
and leave the timer set at 0 time.
Tighten knob set screw and set
timer and knob to suit, approx. 20
seconds.
Check to see if the blower relay
will operate.  If not, replace relay.
Check motor to see if it will
operate on normal nameplate
electrical power.  If not, replace the
motor.
Check to see that all wires and
connections are tight.  If not,
replace the wires and tighten
connections.
Check switch to see that it oper-
ates and will carry current.
Replace switch if necessary.
Timer knob may slip on the shaft
and leave the timer set at 0 time.
Tighten knob set screw and set
timer and knob to suit, approx. 8
seconds.
Check timer operation.  See if
timer switch operates properly.  If
not, replace timer.
Check to see if relay will operate
on rated current and if contacts
will carry current.  If not, replace
relay.
PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
(7) Blower motor won’t start,
machine won’t steam (Cont.)
(8) Blower motor won’t start,
machine steams continuously
after air switch is operated.
(9) Blower motor will start,
machine steams only while
control knob is pushed.