Bunn CDS-3 User Manual

Page of 34
24
SERVICE (cont.)
LAMP CORD CONNECTOR
If  continuity  is  present  as  described,  the  lamp  cord 
connector is operating properly.
If continuity is not present as described, replace the 
lamp cord connector.
Removal and Replacement:
1.  Disconnect the lamp cord assembly from the lamp 
cord connector.
2.  Remove  the  six  #8-32  screws  securing  the  rear 
cover to the dispenser.
3.  Disconnect the lamp cord connector wires from 
the dispenser main wiring harness.
4.  Remove nut and washer securing the lamp cord 
connector to the dispenser. Remove and set aside 
the insulating washers and discard nut, washer and 
lamp cord connector.
5.  Remove new nut and washer from new lamp cord 
connector.
6.  Install the insulating washers to the hole in the top 
of the dispenser. Push new lamp cord connector 
through the holes in the insulating washers and 
secure with the new nut and washer.
7.  Reconnect the wires on the cord connector to the 
dispenser main wiring harness.
8.   Connect the lamp cord to the lamp cord connec-
tor.
9.  Install the rear cover to the dispenser and secure 
with six #8-32 screws.
FIG. 20 LAMP CORD CONNECTOR
P1928
FIG. 19 LAMP CORD CONNECTOR
P1923
Location:
The lamp cord connector is located on top of the 
dispenser.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the lamp cord from the lamp cord con-
nector.
3.  Disconnect the plug on the dispenser main harness 
from the connector from the lamp cord connector.
4.   Check the voltage across the two pin holes on the 
main harness plug with a voltmeter and Day/Night 
switch in the “DAY” position and the “ON/OFF”  switch 
in the “ON” position. Verify that the dispenser hop-
per is full and in place, the dispenser probe contact 
is making contact with the CDS liquid level probe, 
and the dispenser door is closed. Connect the dis-
penser to the power source. The indication must be 
approximately 12.6 volts ac.
5.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the wiring 
diagram and check the dispenser main wiring harness.
6.  Check for continuity between pin 1 (red) of the lamp 
cord connector and the center terminal of the lamp 
cord connector. Check for continuity between pin 2 
(black) of the lamp cord connector plug and the lamp 
cord connector body. Check for continuity between 
pins 1 & 2 of the lamp cord connector plug. Continu-
ity must not be present between pins 1 & 2.
To Main Harness
29793 061599