Window Installation 
Window opening measurements:
27" min. to 40" max. (68.6 cm to 101.6 cm) opening width.
19" min. (48.3 cm) opening height.
Through-the-Wall Installation
The wall opening measurements should be:
Height: 18" (45.7 cm) plus twice the thickness of wood used 
to build frame.
Width: 26" (66 cm) plus twice the thickness of wood used to 
build frame.
Depth: 2" (5 cm) minimum to 8" (20.3 cm) maximum.
Electrical Requirements
The electrical ratings for your air conditioner are listed on the 
model and serial number label. The model and serial number 
label is located on the right-hand side of the cabinet. 
Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
Recommended grounding method
This air conditioner must be grounded. This air conditioner is 
equipped with a power supply cord having a grounded 3 prong 
plug. To minimize possible shock hazard, the cord must be 
plugged into a mating, grounded 3 prong outlet, grounded in 
accordance with all local codes and ordinances. If a mating outlet 
is not available, it is the customer's responsibility to have a 
properly grounded 3 prong outlet installed by a qualified electrical 
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 -  
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
A. 27" min. to 40" max. (68.6 cm to 101.6 cm) 
B. 19" min. (48.3 cm) 
A. 18" (45.7 cm)
B. 26" (66 cm)
C. Wood thickness
D. 2" (5 cm) minimum to 8" (20.3 cm) maximum
A
B
B
C
C
A
D
Power supply 
cord Wiring 
requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
230-volt (207 min. - 253 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING