Parameter
Description
Settings
Default Setting
Econn
ECable connection attempt time
1-255 seconds
30 seconds
Ecport
ECable destination TCP port number
Set by user
N/A
Eclport
ECable destination local  IP port 
number (required for E-Cable UDP 
mode only)
Set by user
N/A
Ectmmsec
Cable connection time resolution
Enable, Disable
Disable
Ecudp
ECable UDP mode
Enable, Disable
Disable
Restoring Factory Default Settings
The factory default settings can restored at any time. If you are using the SX-550 Evaluation 
Daughtercard, hold down the test  button for more than five seconds.  If you are not using the evaluation 
board, short GPIO7 on the OEM header to ground (4.7 K-ohm pull-up resistor connected to +3.3VDC) for 
more than five seconds.
Modifying TCP/IP Settings  
You can modify the TCP/IP settings using ExtendView, the web browser interface or the SX-550 module’s 
internal configuration console.  
To modify TCP/IP settings:
1.
Using ExtendView, click the TCP/IP tab. The TCP/IP window displays.
Figure 8  TCP/IP Window