Feature Quick-Reference
Function
Button
Timing
(seconds)
UPS
Status
Description
Power
POWER
ON
0.2
Off
Press the
POWER
ON
/
OFF
button to turn on the Back-UPS and operate on
AC power.
If AC input power is not available the Back-UPS will operate on battery
power.
If AC input power is not available the Back-UPS will operate on battery
power.
POWER
OFF
2
On
Press the
POWER
ON
/
OFF
button to turn off the Back-UPS.
The Back-UPS will continue to provide surge protection to the Surge
Protection outlets.
Protection outlets.
Display
Status Inquiry
0.2
On
Verify the status or condition of the Back-UPS. The LCD will illuminate
for 60 seconds.
for 60 seconds.
Power-Saving mode:
Continuous
Illumination
Continuous
Illumination
2
On
The LCD will illuminate and the Back-UPS will beep to confirm
Continuous Illumination mode is activated.
The LCD will extinguish and the Back-UPS will beep to confirm that
Power-Saving mode is activated. While in Power-Saving mode, the
LCD will illuminate if a button is pressed, then extinguish after 60
seconds of no activity.
Continuous Illumination mode is activated.
The LCD will extinguish and the Back-UPS will beep to confirm that
Power-Saving mode is activated. While in Power-Saving mode, the
LCD will illuminate if a button is pressed, then extinguish after 60
seconds of no activity.
Mute
Event Specific
0.2
On
Disable any audible alarms caused by an event.
General Status
Enable/Disable
Enable/Disable
2
On
Enable or disable the audible alarms. The Mute icon will illuminate and
the Back-UPS will beep one time. The Mute feature will not activate
unless the Back-UPS is operating on battery power.
the Back-UPS will beep one time. The Mute feature will not activate
unless the Back-UPS is operating on battery power.
Sensitivity
6
Off
The Load Capacity icon will flash to indicate the Back-UPS is in
Program mode. Use the
Program mode. Use the
POWER
ON
/
OFF
button to scroll through and
select Low, Medium, and High sensitivity levels. The Back-UPS will
beep to confirm the selection. Refer to “Back-UPS sensitivity settings” on
page 4 for details.
beep to confirm the selection. Refer to “Back-UPS sensitivity settings” on
page 4 for details.
M
ASTER
/
C
ONTROLLED
outlet Enable/
Disable
Disable
2
On
The leaf icon will extinguish to indicate the M
ASTER
outlet feature is
disabled or illuminate to indicate the M
ASTER
outlet feature is enabled.
The Back-UPS will beep once.
Master/Enable
threshold calibration
threshold calibration
6
On
While calibrating the threshold setting, the device connected to the
M
M
ASTER
outlet should be turned off or placed in Standby or Sleep mode.
Once the threshold setting has been selected the Power-Saving icon will
flash 3 times and beep 3 times.
flash 3 times and beep 3 times.
Self-Test (manual)
6
On
The Back-UPS will run a test of the internal battery.
Note: This will happen automatically when the Back-UPS is turned on.
Note: This will happen automatically when the Back-UPS is turned on.
Event Reset
0.2
On
When the Event screen is visible, press and hold
DISPLAY
, then press the
POWER
button to clear the AC failure event counter.
Fault Reset
2
Fault
After a fault has been identified, press the
POWER
ON
/
OFF
button to
remove the visual indication and return to standby status.