Lapara LA-ON-1K-LCD User Manual
www.laparaups.com
LA-ON-LCD
Technical Specifications
LA-ON-LCD SERIES ON-LINE UPS
MODEL
LA-ON-1KLCD (L)
LA-ON-2KLCD (L)
LA-ON-3KLCD (L)
LA-ON-6K-LCD (L)
LA-ON-10K-LCD (L)
CAPACITY
1000VA/800W
2000VA/1600W
3000VA/2400W
6000VA / 4800W
10000VA/8000W
INPUT
Low Line Transfer
160VAC/140VAC/120VAC/110VAC ±5% or
80VAC/70VAC/60VAC/50VAC ±5%
176VAC ±3 @ 100% load
110VAC ±3 @ 50% load
Low Line comeback
175VAC ±5% or 85VAC ±5%
186VAC @ 100% load
12 VAC @ 50% load
High Line Transfer
300VAC ±5% or 150VAC ±5%
300VAC ±3%
Voltage
Range
Range
High Line comeback
290VAC ±5% or 145VAC ±5%
290VAC
Frequency Range
40Hz ~ 70 Hz
46~54Hz @50Hz / 56~64Hz @60Hz
Phase
Single phase with ground
Power Factor
≧ 0.99 @ 220-230VAC (input voltage)
≧ 0.99 @ 100% load
OUTPUT
AC Voltage Regulation (Batt. Mode)
± 3%
± 1%
Frequency Range (Synchr. Range)
47 ~ 53 Hz or 57 ~ 63 Hz
46~54Hz@50Hz / 56~64Hz @60Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio
3:1
Harmonic distortion
≦3% THD (Linear
Load)
≦6% THD (Non-
linear load)
≦4% THD (Linear Load)
≦7% THD (Non-linear Load)
≦3% THD (Linear Load)
≦6% THD (Non-linear Load)
AC Mode - Batt. Mode
Zero
Transfer
Time
Time
Inverter to Bypass
4 ms (Typical)
Zero
Waveform (batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
~ 85%
~ 88%
89%
Battery Mode
~ 83%
88%
BATTERY
Battery type
12V/7AH
12V/7AH
12V/9AH
12V/7AH
12V/9AH
Number
3 6 6
20
20
Typical Recharge Time
4 hours recover to 90% capacity
7 h. recover to
90% capacity
8 h. recover to
90% capacity
Charging current (max)
1.0 A (max)
1.0 A ±10% (max)
Standard
Model
Model
Charging voltage
41.0 VDC ± 1%
82.1 VDC ±1%
273.0 VDC
Battery type
Depending on applications
Number
3
6
6
18 - 20
Charging current (max)
8.0 A
4.0 A
Long-run
Model
Model
Charging voltage
41.0 VDC ± 1%
82.1 VDC ±1%
273.0 VDC @ 20 pcs. batteries
INDICATORS
LCD Panel
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
INTERFACE
Power Output
4xIEC
8xIEC
6xIEC + Terminal
Block
2xIEC + Terminal Block
Communication Ports
1xUSB + 1xRS232 + 1xRJ45
1xUSB + 1xRS232 + 1xRJ45
PHYSICAL
Dimensions, D x W x H (mm)
397 X 145 X 220
421 X 190 X 318
592 X 250 X 576
Standard Model
13
26
28
81
83
Net Weight
(Kg)
(Kg)
Long-run Model
7
13
25
27
ENVIRONMENT
Humidity
20-90 % RH @ 0 - 40°C (non-condensing)
Noise Level
< 45dBA @ 1 m.
< 55dB @ 1 m.
< 58dB @ 1 m.
SOFTWARE MANAGEMENT
Smart RS-232 & USB
Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008/7, Linux, Unix and Mac
SNMP optional
Power management from SNMP manager and web browser
* L means long-run model
* Specifications are subject to change without further notice.
- 18 -