Fantec TC-2U50ES 80Plus 2506 User Manual

Product codes
2506
Page of 5
 
SURE STAR COMPUTER CO., LTD 
No. 2-1, Daan Road, Shulin City Taipei 238 , Taiwan 
E-mail: info@tc-surestar.com.tw                  Tel: +886 2 2682 2505 
http: //www.tc-surestar.com.tw                      Fax: +886 2 2682 2515
 
 
MODEL : SS-2U50ES    (> 80%) 
1. Specification 
1.1.AC Input Voltage Range: 100VAC  ~  240VAC, 
10%, 47 to 63 Hz. 
1.2.INPUT CURRENT:8.0 A ( RMS ) FOR 115VAC /4.0 A ( RMS ) FOR 230VAC. 
1.3. Input Power Factor: The minimum power factor at full load shall be   
0.98/115V 60 Hz and 0.95/230V 50 Hz. 
1.4.
 
Inrush current: 35A MAX. FOR 115 VAC / 55A MAX. FOR 230 VAC. 
1.5.DC Output: 400W maximum. 
 
Output-1  Output-2  Output-3  Output-4  Output-5 
Output Voltage 
+5V DC  +12V DC  -12V DC  +3.3V DC  +5VSB   
Output Current(Max) 
25A 
40A 
0.8A 
25A 
3.5A 
Output Current(Min.) 
0.5A 
2A 
0A 
0.5A 
0.1A 
Ripple/Noise Max.(P-P) 
60mv 
120mv 
120mv 
60mV 
60mV 
Line Regulation 
±1﹪ 
±1﹪ 
±1﹪ 
±1﹪ 
±1﹪ 
Load Regulation 
±5﹪ 
±5﹪ 
±5﹪ 
±5﹪ 
±5﹪ 
Note: 
1. Noise Test – Noise bandwidth is from DC to 20 MHz.                                                           
2. Ripple frequencies greater than 1MHz shall be attenuated by the measurement 
System. 
3.Add 0.1uF/10uF capacitor at output connector terminals for ripple and noise   
            measurements. 
4.The combined total power from 5V & 3.3V shall not exceed 170W. 
 
 
1.3 PS-ON 
  Remote On/Off Control: 
      When PS-ON is pulled to TTL Low, the DC output is to be enabled. 
      When PS-OFF is pulled to TTL high, the DC output is to be disabled. 
1.4 PW-OK 
      PW-OK is power good signal and should be asserted high by the power   
      supply to indicate that +5VDC and +3.3VDC output are above the under   
      voltage thresholds of the power supply TTL. compatible signal out with 
      100ms to 500ms.