Fantec TC-2U50ES 80Plus 2506 User Manual

Product codes
2506
Page of 5
 
                        Timing of PS-ON, PW-OK, and Germane Voltage Rails 
 
      Although there is no requirement to meet specific timing parameters, 
      The following signal timings are recommended: 
2ms T2 200ms
 
100ms≦T3 500ms
 
T4>1ms 
T5 10ms
 
1.8 Efficiency: TYPICAL >80% AT 115VAC , FULL LOAD.   
1.9.Hold-Up Time: 16ms at maximum load & normal input voltage. 
                                                           
2.PROTECTIONS 
  
2.1 OVER-VOLTAGE PROTECTION 
       
OUTPUT 
Min 
        Max 
+3.3V 
3.7V 
4.1V 
+5V 
  5.7V 
    6.5V 
+12V 
  13.1V 
    14.5V 
 
2.2 SHORT CIRCUIT PROTECTION 
        A short circuit placed between the DC Return and the output shall cause 
        No damage and the power supply shall shutdown. 
  2.3 OVER POWER PROTECTION 
        The power supply shall shut down when output power exceeds 110﹪to 160﹪ 
        of full load and require a power on cycle be performed by the operate 
2.4 NO LOAD OPERATION 
        No parts shall be damaged on the power supply. 
3. ENVIRONMENT TEMPERATURE 
  3.1 Operation Temperature: 0℃ to 45℃ 
  3.2 Cooling: ONE 60mm DC FANS. 
3.3 Storage Temperature:-20℃ to 70℃ 
  3.4 Humidity: 5 to 90﹪non-condensing.