6.3 
Taring 
 
Switch-on the balance using the 
 key and wait for the 
„0“ display. 
 
Put the tare vessel on the weighing plate and press the 
 key. The balance 
display goes to „0“. The weight of the container is now internally saved. 
If after finishing the weighing process the 
 key, is pressed 
again, „0“  appears 
anew in the display.  
 
The taring process can be repeated any number of times, e.g. when adding several 
components for a mixture (adding). 
The limit is reached when the whole weighing range is exhausted. 
After removing the taring container the total weight is displayed as negative display. 
 
6.4  PRE-Tare function 
 
Using this function the weight of a tare vessel can be stored. 
This value also remains saved if the balance meanwhile has been switched off and  
switched on again. 
Switch-on balance using the 
 
key and wait for the „0“ display. 
Put tare vessel on the weighing plate and press the 
 
key 6 times until „PtArE“ 
flashes on the display. By actuating the 
 key, the current weight on the weighing 
plate is saved as PRE-Tare weight. 
 
To switch off this function, unload the weighing plate and press the 
 key 6 times, 
until „PtArE“ flashes on the display. Then press the 
 key. The stored PRE-Tare 
weight is deleted. 
 
 
6.5  Plus/minus weighings 
For example unit weight control, fabrication control etc. 
Switch-on the balance using the 
 key and wait for the 
„0“ display. 
Put the no
minal weight on the weighing plate and tare to „0“ using the 
 key. 
Remove the nominal weight. 
Put the test objects subsequently on the weighing plate, the respective deviation 
from the nominal weight is displayed with the re
spective sign to „+“ and „-“. 
According to the same procedure also packages with the same weight can be 
produced, referring to a nominal weight. 
Back to weighing mode by pressing the 
 key.