SOEKS IMPULSE Magnetic field-analysis apparatus, Magnetic field tester 9 Data Sheet

Product codes
9
Page of 52
-38-
Measure
 
The instrument can operate in one of four electromagnetic field 
level measurement modes: 
 
● EMF in LIVE BUILDING
 
● EMF in LIVE AREA
 
● EMF of PC
 
● View 
 
"EMF in LIVE BUILDING", "EMF in LIVE AREA", and "EMF 
of PC" modes have preset thresholds for audible, color and text warning 
triggering according to the norms (Table 2).
                                                                                                           
 Table 2
                Mode 
             Electric field      Magnetic field      Averaging      
                                                threshold, V/m     threshold, uT          degree                             
EMF in LIVE BUILDING 
     500 
               10 
    10
EMF in LIVE AREA                        1000                 25 
    10
EMF of PC 
                       25 
             0,25 
    40
View  
                                         no 
              no 
    40
 
When the threshold limit is exceeded, a corresponding message is 
displayed on the red background and an interrupted alarm sounds. The signal 
can be enabled or disabled by the "Alarm" parameter setting
[Main menu] - [Settings] - [Sound] - [Alarm] 
 
The average measurement time is 500 ms. Measurement data are 
averaged (averaging degree for each measurement mode is specified in the 
Table 2). A root-mean-square value of all values along measurement axes is 
displayed as an electric and magnetic field intensity. An instant value for 
each measurement along each axis is also displayed in a form of graphic 
column (page 33). 
 
A limit of column filling in different modes is specified in the 
Table 3:
                                                                                                           
 Table 3
                Mode 
             Electric field column    Magnetic field column       
                                                        limit, V/m                           limit, uT     
                                                             
EMF in LIVE BUILDING 
          2000 
                25
EMF in LIVE AREA                              5000 
               50  
EMF of PC 
                              50                                  500  
View                                                        3300 
             29-46
 
 
The  instrument  is  equipped  with  two  antenna  sensors  for 
measurement of electric field along X and Y axis and with three sensors for 
magnetic field measurements along X, Y, and Z axes. The axes correspond to 
the axes of three-dimensional orthogonal coordinate system. The figure 
displays the location of the axes with relation to the instrument image.
 
 
 
 
 
During the source search it is essential to analyze the instant 
values along individual axes for the purpose of source direction identifica-
tion. 
 
The switching between modes is performed circle-wise by 
pressing the right button, [NEXT].