SOEKS IMPULSE Magnetic field-analysis apparatus, Magnetic field tester 9 Data Sheet
Product codes
9
● EMF in LIVE AREA
Set the "EMF in LIVE AREA" mode
Bring the instrument into the monitored area, holding it with your
fingers at arm's length at a height of 1–2 meters above the ground or other
surface. Keep instrument in the monitored area not less than 10 seconds prior
to reading out the result. Measures should be taken in case of appearance of
"HIGH LEVEL OF ELECTRIC FIELD" or "HIGH LEVEL OF
MAGNETIC FIELD" messages on the red background.
The possible reasons for threshold crossing are: proximity of
power cable, wiring defect, proximity to the electric devices (e. g. elevator
motors), proximity to the base stations, crossing of the tracks of radio relay
stations, proximity to the power lines, etc. Long stay of people and domestic
animals in such areas should be avoided; in case of significant excess staying
there may result in electrical shock.
● EMF of PC
Set the "EMF of PC" mode
Take measurement according to the procedure specified in
Appendix 3.
Measurement time in this case should be not less than 30 seconds.
For the purpose of reducing electromagnetic field distortion generated by
human, it is advisable to fix the instrument on an electrically neutral stand, e.
g. plastic chair, for the time of measurement.
● Localization of hidden electric wiring
The instrument can be used for the localization of a hidden
electric wiring in walls or furniture.
To do this, it is convenient to use graphic electric and magnetic
field level indicators, displaying not average but instant value of the
corresponding field parameter.
Select the required range for instant field level display by an
experimentation. If the field is weak, use «EMF of PC» mode; if the signal
exceeds the display range, use other modes.
-41-