12.9
System Control Block (SCB)
The System Control Block (SCB) provides system implementation information, and system control. This includes 
configuration, control, and reporting of the system exceptions.
Ensure that the software uses aligned accesses of the correct size to access the system control block registers:
Except for the SCB_CFSR and SCB_SHPR1–SCB_SHPR3 registers, it must use aligned word accesses
For the SCB_CFSR and SCB_SHPR1–SCB_SHPR3 registers, it can use byte or aligned halfword or word 
accesses.
The processor does not support unaligned accesses to system control block registers.
In a fault handler, to determine the true faulting address:
1. Read and save the MMFAR or SCB_BFAR value.
2. Read the MMARVALID bit in the MMFSR subregister, or the BFARVALID bit in the BFSR subregister. The 
SCB_MMFAR or SCB_BFAR address is valid only if this bit is 1.
The software must follow this sequence because another higher priority exception might change the SCB_MMFAR 
or SCB_BFAR value. For example, if a higher priority handler preempts the current fault handler, the other fault 
might change the SCB_MMFAR or SCB_BFAR value.