Conrad CCFL4.1-300 Blue Cold Cathode Tube Lamp 300mm CCFL4.1-300 Data Sheet

Product codes
CCFL4.1-300
Page of 4
 
3.2.1 The testing of the electrical and optical characteristic should start when the lamp has been 
running for more than 3 minutes under the required testing current. The lamp should be placed 
horizontally. 
3.2.2 The ambient temperature is 20℃±2℃,and 65%±20% for the ambient humidity without any air 
movement. 
3.2.3 Testing Equipment 
Testing Item 
Equipment 
Input voltage、current 
Digital multimeter DT9806 
Starting volt、lamp volt 
1:100 high pressure detector/Tektronix TDS 1012B 
Lamp current 
Fluke(8086 A) 
Surface luminance 
Colored photometer(BM-7  Topcon) 
Color 
Temperature
、 
Chromaticity 
Colored photometer(BM-7  Topcon) 
3.2.4 Working condition:-10℃~80℃, relative humidity below 70%,Saving condition:-20℃~90
℃ relative humidity below 80%. 
3.4  Testing method: 
 3.4.1 The testing circuit of starting voltage, lamp voltage, lamp current is as the pictureⅠ. 
 A. The length of line d-e and f-g is both 300±10mm(without the equipment for IL) 
B. The lead wire for testing the loop should not be placed in parallel otherwise it may influence 
the testing accuracy. 
C. When IL is tested, disconnect the VL testing equipment. When VL is tested, connect the IL 
testing equipment to the wire. 
D. Lamp should be tested on the special testing lamp-support. The background should be black 
with no reflecting light. 
3.4.2 Note: The testing result would be different when testing equipment varies. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
 
 
Tektronix 1:100 high  
                                   Pressure detector 
PictureⅠ 
  
+ - 
Tektronix 
TDS1012B 
IN                                          OUT                         
GND                                      GND 
Vin 
mA 
Probe 
(100:1) 
      VL 
  Inverter 
      IL