Conrad 12 Vdc delayed action timer relay module 193631 Data Sheet

Product codes
193631
Page of 4
Attention! Read carefully! 
 
The 
warranty 
claim 
shall 
lapse 
with 
damages caused due 
to 
failure  to 
follow instructions. 
 
This timer relay  serves  the  purpose  of  switching  on  and  off  the  devices. The  timer  is 
activated when the control voltage is supplied and is again deactivated after the course 
of  easily  adjustable  interval  time  (switch  off  delay). If  the coding plug  is  adjusted 
on switch  on  delay,  then  the set  time progresses  with  the  supply  of  operating  voltage  
(Relay is still in idle position). The relay is activated after the course of delay time. The 
relay  is  again  switched  back  to  the  idle  position  with  any  interruption  in 
control voltage. The  switch  status  (supplied  control voltage,  activated  relay) is 
displayed via LEDs. 
 
This  article  has  been  tested  as  per  the  EC  guidelines  89/336/EEC (Electromagnetic 
Compatibility  Law,  dated, 09.11.1992)  and complies  with  the  statutory  requirements. 
Technical data: 
 
Control voltage   ................. : 12, 24V= ± 10% 
Rated consumption ............ : approx. 1 W 
Rated current    ................... : 12V 75 mA, 24 V approx. 40 mA 
Equipment          .................. : 1 Relay with 1 changeover contact 
Switch voltage          ........... : 250 V AC 
Rated current    ................... : 5 A 
Max. Switching output   ..... : (ohm load) 1100 VA~ 
 
 
 
 
    (ohmic load in W) 
 
 
 
 
    24V = 120 
 
 
 
 
    48V = 75 
 
 
 
 
    20V = 30 
 
INSTALLATION 
 
The on and off switch delay time is set up with the 
help of a small screwdriver with P1 trimmer 
potentiometer. 
 
 
 
PROGRAMMING 
Switching OFF delay
 
 
If the link plug is plugged in the 3-pin multi-pin 
connector at "AV" = switching off delay, then the 
relay is immediately activated with the supply of 
control voltage. The timer is deactivated after the