3. „Step Button (REL->REL+SEQ->OFF)“
Operation of the button at the input „SET“ toggles the relay output on, its sequence output on and then both outputs off in sequence.
First operation of the button at the input „SET“ => relay output activated, sequence output deactivated.
Second operation of the button at the input „SET“ => relay output remains activated, sequence output is activated.
Third operation of the button at the input „SET“ => relay and sequence output are deactivated, etc.
When a button is pushed at the input „RESET“ both outputs will be deactivated. After a reset, the function is re-started if the button at the input
„SET“ is pushed (starting with activated relay outputs).
4. „Step Button with Switch-Off Delay“
Operation of the button at the input „SET“ toggles the switching condition of the device in the order „Relay on“ -> „Sequence on“ -> „Completely
OFF“ with adjustable deactivation delay (starting with activated relay output).
First operation of the button at the input „SET“ => relay output is activated for the set time T1.
Second operation of the button at the input „SET“ => sequence output is activated for the set time T2.
Third operation of the button at the input „SET“ => relay and sequence output are deactivated, etc.
When a button is pushed at the input „RESET“ both outputs will be deactivated. After a reset, the function is re-started if the button at the input
„SET“ is pushed (starting with activated relay outputs).
RELAIS
SEQUENZ
SET
RESET
<-------------T1------------->
<-------------T2------------->
<-------------T2------------->
<-------------------T1------------------->
SET
<-------------T1------------->
SEQUENZ
RELAIS
RESET
<-------------T1------------->
RESET
RELAIS
SEQUENZ
SET
<-------------------T2------------------->
<---------------T2---------