Conrad 393903 time 393903 Data Sheet

Product codes
393903
Page of 17
15
e) Other Functions
1. „Power Surge Switch“ (On/Off Switch)
If the button at the input „SET“ is pushed, this causes the relay to toggle („ON“ <-> „OFF“).
The push of a button at the input „RESET“ deactivates the relay output immediately.
2. „Presence Simulation (Randomly Controlled)“
If the button at the input „SET“ is pushed, a positive level is pending and the switch between switch-on delay (T1) and break time (T2) takes place
at once, starting with the activation time T1. The two times are random values between the minimum and maximum time entered by PC software.
If the button at the input „SET“ is pushed while the function is already running, this has no effect on the relay output.
The push of a button at the input „RESET“ deactivates the relay output immediately.
3. „Set => On, Reset => Off“
If the button at the input „SET“ is pushed, the relay is activated at once.
The push of a button at the input „RESET“ deactivates the relay output immediately.
<-T1-> <-T2->
-------->
<-T1-> <-T2-> <---T1--
RESET
RELAIS
<-------T1------->
SET
<-------------T1-------------> <-----------T2-----
<-------------------T1-------------------> <-------------------T2------------------->
RESET
RELAIS
SET
<-------T2------->
SET
RESET
RELAIS
SET
RESET
RELAIS