Honeywell evohome Wireless indoor thermostat HCW82 Data Sheet

Product codes
HCW82
Page of 32
Changing batteries 
 
10 
3.4. Installing 
the window contact 
► 
Connect any sensor with floating contact to the HCW 82 
(installation to connection 1 and connection 2, see 
Fig. 7(2), Page 9). 
► 
Assign the HCW 82 to the Hometronic Manager 
HCM 200D as a sensor (refer to the HCM 200D 
instructions "Assigning a room to a sensor"). 
 
 
If several floating contacts are used, these have 
to be connected in series. 
 
 
4. Changing 
batteries 
Change the batteries if the red LED of the room temperature 
sensor flashes and the device is not in test mode. 
► 
Remove the housing cover of the HCW 82/HCF 82  
(see Fig. 1). 
► 
Remove the batteries. 
 
Dispose of the batteries according to the 
local statutory requirements and not with 
the used domestic refuse. 
 
 
Always replace both batteries together. 
Only use 1.5 V batteries of the type LR06, AA. 
 
► 
Insert the batteries with the right polarity into the batteriy 
compartment (see Fig. 2). 
► 
Place the housing cover on at the top and latch it in 
downwards (see Fig. 4). 
 
5. Checking 
radio 
transmission 
The HCW 82/HCF 82 can send a test signal to the allocated 
receiver (for example an underfloor heating controller) in 
order to test the signal strength. 
► 
Keep the teach-in button pressed for at least 30 s until the 
red LED extinguishes.  
The device is now in test mode and sends a test signal 
every 5 seconds. 
The LED flashes briefly at every test signal. 
► 
Check the radio transmission at the receiver. Refer to the 
respective instructions for information about receiving and 
evaluating the test signals. 
 
 
The test mode is terminated automatically after 
5 minutes. The test mode can also be terminated 
by removing the batteries, disconnecting the 
power supply or by pressing the teach-in button. 
 
 
 
 
 
 
 
 
 
6. 
Help with problems 
 
Problem Cause 
Remedy 
Batteries 
inserted 
incorrectly 
► 
Insert the batteries 
correctly. 
Teach-in failed 
Radio 
connection 
failure  
► 
Eliminate interference 
sources (metal, wireless 
devices). 
► 
Correct installation site. 
► 
Repeat the teach-in. 
Batteries 
inserted 
incorrectly 
► 
Insert the batteries 
correctly. 
Radio 
connection 
failure  
► 
Eliminate interference 
sources (metal, wireless 
devices). 
► 
Repeat the teach-in. 
No measured 
data at 
Hometronic 
Manager 
Module not 
assigned or 
assigned 
incorrectly 
► 
Repeat the teach-in. 
► 
Check the assignment. 
If appropriate, repeat. 
Window contact 
is ignored 
Window 
contact not 
assigned 
► 
Repeat the teach-in for 
the window contact. 
 
7. Technical 
data 
 
Batteries 
1.5 V, type LR06, AA 
Power supply unit  3 V DC 
±
 10 %, min. 25 mA 
Cable for power 
supply unit/window 
contact 
 
2x0.8 mm; 2x0.5 mm² 
max. length 100 m 
Frequency 868.3 
MHz 
(transmitter) 
 
8. WEEE 
directive 
2002/96/ 
EC - Waste Electrical and 
Electronic Equipment 
directive 
 
► 
At the end of the product life dispose of 
the packaging and product in a 
corresponding recycling centre.
 
► 
Do not dispose of the unit with the usual 
domestic refuse.
 
► 
Do not burn the product.