13.5
Transaction Router C-Unit Message Registers
13.5.1
CUNIT_REG_DEVICEID—Offset 0h
CUnit Configuration Register Device ID/Vendor ID. Device ID and Vendor ID Strapped 
in from top level. Reset value to strapDID[15:3],fuse[2:0], 16'h8086 these bits can be 
re-written from SETIDVALUE message 1st DW data byte 2, byte 3
Access Method
Default: 00008086h
Table 161.
Summary of C-Unit Message Bus Registers—Port 0x08 
Offset
Register Name (Register Symbol)
Default 
Value
0–0h
00008086h
1–1h
00000007h
2–2h
06000000h
3–3h
00000000h
B–Bh
00000000h
3E–3Eh
00000000h
Type: 
Message Bus Register
(Size: 32 bits)
Offset: 
Op Codes:
h - Read, h - Write
31
28
24
20
16
12
8
4
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 1 1 0
DEVIC
E
ID_VEN
DOR_ID
DE
VICEID_BIT
_
22_19
DE
VICEID_BIT
_
18_16
DE
VICEID_BIT_15_0
Bit 
Range
Default & 
Access
Field Name (ID): Description
31:23
0h
RW
DEVICEID_VENDOR_ID: 
Device ID and Vendor ID bit [15:7] are strapped in from top 
level. These bits can be re-written from SETIDVALUE message 1st DW data byte 2, byte 
3. for VLV/VLV2, final setting of this field is from SETIDVALUE message, while for TNG it 
uses the strapped setting. For all SOC's, the RDL defalut is set to the strapped setting in 
that SOC. Please refer to the SoC documentation to determine the proper Device ID for 
the chip.
22:19
0h
RO
DEVICEID_bit_22_19 (DEVICEID_BIT_22_19): 
Device ID [6:3] Hardwired in the 
design. SETIDVALUE message will not re-write this field. RDL default is set to the 
strapped value
18:16
0h
RO
DEVICEID_bit_18_16 (DEVICEID_BIT_18_16): 
Device ID [2:0]. Strapped in from 
top level and tied to fuses to determine product SKU. SETIDVALUE message will not re-
write this field.