10.0   Maintenance and Storage 
 
At least once a year a check should be made of your EIM HQ Series Actuator 
 
ƒ  Disconnect all power to actuator. 
ƒ  Open Electrical Enclosure.  Inspect and tighten all electrical connections 
ƒ  Visually inspect for any electrical or mechanical damage.  Replace worn or damaged components. 
ƒ 
Check lubrication consistency and levels.  Fill or replace if required.
 
 
Actuators must be stored in a clean, cool and dry area.  The unit shall be stored with the cover installed and the    
conduit openings sealed.   Storage must be off the floor, covered with a sealed dust protector. 
 
 
11.0 Trouble 
Shooting 
 
The following instructions are offered for the most common difficulties encounter during installation and 
start-up
.   
 
 
SYMPTOM 
PROBABLE CAUSE 
CORRECTIVE ACTION 
Motor will not Run 
Open in control circuit 
Refer to appropriate wiring diagram 
 
 
and check for continuity 
 
Insulation resistance breakdown in motor 
Perform Megger Test 
No power available to actuator 
Tripped circuit breaker 
Reset circuit breaker 
Manual Override Nut hard to turn 
Valve stem improperly lubricated 
Lubricate with grease 
 
Actuator lubrication has broken down 
Clean out old grease and replace 
 
  
with recommended lubricant 
 
Valve packing gland too tight 
Loosen packing gland nuts as  
  
 
necessary 
  
Jammed valve 
Refer to valve maintenance 
Valve only opens or closes 
Limit switch improperly set 
Check setting and reset if necessary 
partially with motor 
 
 
Manual Override Nut will not 
Stripped gearing 
Replace as necessary 
Operate valve 
Broken handwheel shaft 
Replace as necessary 
  
Broken valve stem 
Repair or replace as necessary 
Motor runs but will not operate 
Stripped gearing 
Replace as necessary 
valve