CALIBRATING THE DISPENSER (Cont.)
 
LCD DISPLAY 
 CALIBRATION MODE 
 DESCRIPTION
Right (Decaf) Water Rate
Enter Liters collected from the 20 sec. 
test above.
Default = 1.08
Range = 0.95 - 1.12 Liters
Cooler Control Temperature
Delays the Pump turn off after a 
dispense.
Default = 200
Range = 1 - 999 mSec.
Reset Factory Defaults
Resets all set up values to the Factory 
Default setting.
Hold both Increase (+)  and  Decrease 
(-) switch for 10 seconds.
Displays Software Version # -
Exits To Home View After 3 Seconds.
English or Metric Mode
Used to select the desired units.
Default = English
Eng for English
S.I. for Metric
Error Code Memory
Display cycles through the last (3) 
Error Codes.
Erase by holding both the Decrease (-) 
& Increase (+) switches for 10 sec.
39288 072707
Pump “OFF” Delay
Used to set the Target Temperature for 
the Product Cabinet.
Default = 65°F (18°C)
Range = 50° - 75°F (10° - 24°C)
MENU
(-)
(+)
C 4 1.0 8
MENU
(-)
(+)
C 5 0 6 5
MENU
(-)
(+)
- - -
C 9
MENU
(-)
(+)
x x
C
L
MENU
(-)
(+)
C 6 2 0 0
MENU
(-)
(+)
C 8 E x x
MENU
(-)
(+)
C 7 En g
Maximum Cooling Mode
Set Product Cabinet Target Temperature 
to 50°F (10°C). Then continue to hold 
the decrease (-) switch for 10 sec. Unit 
will display “CHL”. Chiller will now 
attempt to cool the product cabinet to 
45°F (7°C). To disable this mode, hold 
the increase (+) switch for 10 sec. Then 
adjust to the desired Cabinet Temp.
NOTE: All Cabinet Temperature 
Warnings are disabled when in the 
Max. Cooling Mode.
MENU
(-)
(+)
C 5 CH L