TROUBLESHOOTING GUIDE (Cont.)
Error Codes (Continued)
 
LED DISPLAY 
 ERROR 
 DESCRIPTION/TROUBLESHOOTING
Tank Temp Sensor Failed
Sensor Reading Out Of Range (High 
or Low). Faulty Sensor wiring.
Switch Board Failure
Unable To Communicate With The 
Switch Board In The Door. Faulty 
wiring between the Door and the Main 
Control Board.
39288 072707
Power Supply Failure
Power Supply voltage is outside the 
allowable limits (23 - 26 Vdc). Faulty 
wiring. Blown fuse inside Power 
Supply, failed supply.
Heat Sink Temp Too High
Cool Temp Sensor Failed
Sensor Reading Out Of Range (High 
or Low). Faulty Sensor wiring.
Heat Sink Temp Sensor Failed
Sensor Reading Out Of Range (High 
or Low). Faulty Sensor wiring.
MENU
(-)
(+)
6
C
E
0 0
MENU
(-)
(+)
7
C
E
0 0
MENU
(-)
(+)
8
C
E
0 0
MENU
(-)
(+)
9
C
E
0 0
MENU
(-)
(+)
0
C
E
0 1
MENU
(-)
(+)
1
C
E
0 1
WARNING: Empty BIB LED’s flash 
slowly. Heat Sink Temp above 150°F 
(65°C). Check: Air Filter plugged or 
blocked, Ambient Operating Temp Too 
High >90°F (32°).
FAULT: All LED’s Flash& Chiller Turned 
OFF.
Heat Sink Temp above 170°F (77°C). 
Check: Air Filter plugged or blocked, 
Ambient Operating Temp Too High 
>90°F (32°).