Whirlpool T-K2 User Manual

Page of 32
Operation
 
 
General 
The Flash Water Heater is an instantaneous, 
tankless water heater designed to efficiently 
supply domestic or commercial hot water. The 
principle behind the Flash water heater is 
simple: Once a hot water tap is opened, the 
Flash’s flow sensor detects that hot water is 
needed, and automatically commands the 
computer to electronically ignite the burners, 
and heat water. During operation, the 
computer monitors the water temperature and 
flow rate, and controls the gas flow and fan 
speed to maintain a constant output 
temperature. After the burners are ignited the 
“fire on” lamp will be lit. 
 
 
0.75 gallons per minute is required to turn the 
burners on, but after the burners are ignited, 
the flow rate can drop to 0.6 gallons per 
minute without the burners turning off. 
As long as water, gas and electricity are 
connected, there will be an endless flow of hot 
water. To turn on your water heater, just open 
a tap. To turn the heater off, just close the tap. 
 
Turning It On
 
 
To turn on the Flash water heater 
1.  Open a hot water tap, or turn on water 
demanding appliance. 
2. Unit will detect flow, burners will ignite, 
“Fire On” lamp will light up. 
 
 
 
3.  If necessary, mix in cold water to get a 
comfortable temperature. 
 
 
Turning It Off 
 
To turn off the Flash water heater 
1.  Close the hot water tap, or turn appliance 
off. 
2.  Flow will diminish, unit will shut off. 
3.  “Fire On” lamp will go out. 
 
 
Temperature
 
 
The output temperature of the T-K2 has been 
factory set for a maximum 120
°
 F (50
°
 C). 
This is electronically controlled by the 
computer and can be adjusted with a TK-
RE01 temperature controller, or with the 
dipswitches on the computer board (See pgs. 
21-22 for dipswitch settings). Further 
adjustment may be made by mixing in cold 
water with the hot to obtain the ideal water 
temperature. 
The flow rate possible out of the unit is 
dependent on the temperature setting chosen.  
Consult the flow charts on the last page of this 
unit to determine the possible outlet 
temperature and flow rate combinations. 
 
WARNING:  Temperatures above 125º F (52º 
C) can cause severe burns or death from 
scalding. Children, the disabled and the 
elderly are at a high risk of being injured. Feel 
the water temperature before bathing or 
showering. Do not leave children, disabled 
persons, or the elderly unsupervised.  
 
Flow