Honeywell Optiflex User Manual

Page of 24
2-1 
S E C T I O N   2  
 
Mounting, Wiring, and Setup 
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
 
In This Section 
♦ 
Setup Considerations 
♦ 
Mounting Optiflex
 
♦ 
Wiring and Setup of Optiflex 
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •  
Setup Considerations 
Cameras connected to Optiflex can either be triggered by system events from a Honeywell 
Vista control panel, from the voltage triggers provided, or both.  Optiflex can also be used 
without any triggers at all, if the system is configured to automatically scan the cameras one 
at a time, or if the cameras are always on.  If using the voltage triggers, refer to the table 
below to determine which camera each voltage trigger turns on.  
 
Voltage Trigger 
Function 
Captures Video on Camera 1 
Captures Video on Camera 2 
Captures Video on Camera 3 
Captures Video on Camera 4 
Captures Video on Camera 5 
Captures Video on Camera 6 
7 NTSC 
Advance 
Captures Video on All Cameras 
If using a Honeywell Vista control panel, the cameras are turned on using Output (relay) 
Programming commands in the control panel.  To accomplish this, enable a 4204 Relay 
Module in the system’s Device Programming Mode as Device Address 12.  Then program 
eight logical relays and point to the same four physical relays twice, programmed as shown 
in the table below, using system events or zones/zone lists as desired to turn on the relays as 
shown below.  Cameras are turned on through the ECP (Data In and Data Out) connections 
(See “Wiring and Setup of Optiflex”) in this section, and the control panel’s Programming 
Guide for information on how to program output relays. 
  
 
4204 Output Command (4204 on ECP Address 12) 
Function 
Relay 1: Turn ON for 2 seconds 
Captures Video on Camera 1 
Relay 2: Turn ON for 2 seconds 
Captures Video on Camera 2 
Relay 3: Turn ON for 2 seconds 
Captures Video on Camera 3 
Relay 1: Continuous Pulse 
Captures Video on Camera 4 
Relay 2: Continuous Pulse 
Captures Video on Camera 5 
Relay 3: Continuous Pulse 
Captures Video on Camera 6 
Relay 4: Continuous Pulse 
NTSC Advance 
Relay 4: Turn ON for 2 seconds 
Captures Video on All Cameras