Whirlpool GZ9736XS Leaflet

Page of 1
12" (30.5 cm) min.
14" (35.6 cm) max.
30" (76.2 cm)
or
36" (91.4 cm)
33
⁷⁄₁₆”
(85 cm)
max.
24" (61 cm) min.
30" (76.2 cm) suggested max.
10
¹⁵⁄₁₆"
(27.8 cm)
8
¹⁵⁄₁₆"
(25.2 cm)
32"
(81.3 cm) min.
46
¹⁄₈"
(117.2 cm) max.
5
¹⁄₁₆"
(12.9 cm)
7⁷⁄₈"
(20 cm)
19
¹⁄₁₆"
(48.4 cm)
30" (76.2 cm)
or
36" (91.4 cm)
19
⁵⁄₈"
(49.8 cm)
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
GZ9730XS
GZ9736XS
A 120 Volt, 60Hz., AC only 15-amp fused, electrical supply (or circuit
breaker) is required. (A time-delay fuse or circuit breaker is
recommended.) It is recommended that a separate circuit serving only
this appliance be provided.
Set the grounded 3 prong outlet within the space covered by the
decorative flues.
30" (76.2cm) and 36" (91.4cm) Wall-Mount Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.
Ref. W100297700A
1-22-08
3-1/4" x 10”
(8.3 cm x 25 cm)
elbow
wall
cap
Maximum length  
=  35  ft. (10.7 m)
1 — 90° elbow 
= 5.0 ft. (1.5 m)
8 ft. (2.4 m) straight 
= 8.0 ft. (2.4 m)
1 — wall cap 
= 0.0  ft. (0 m)
Length of system 
=13.0 ft. (3.9 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
3-1/4" x 10" (8.3 cm x 25 cm) vent system
Note:
Flexible vent is 
Not recommended.
®
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.  
A. Roof cap
B. 6" (15.2 cm) 
round vent
A. Wall cap
B. 6" (15.2 cm) 
round vent
A. Deflector
B. 6" (15.2 cm) 
round vent
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)
A
A
B
B
B
A
Roof Venting
Wall Venting
Non-vented 
(recirculating)