Westinghouse CONTRACTOR SERIES 10KPRO FULLY FEATURED Owner's Manual

Page of 106
  
25
OPERATION
!
 WARNING
Be sure the generator is properly 
connected to earth ground before 
operating. The generator must be 
grounded to prevent electrical shock 
due to faulty appliances.
POWER CORD
Using Extension Cords
Westpro Power Systems assumes no responsibility for 
the content within this table. The use of this table is the 
responsibility of the user only. This table is intended 
for reference only. The results produced by using this 
table are not guaranteed to be correct or applicable in 
all situations as the type and construction of cords are 
highly variable. Always check with local regulations and 
a licensed electrician prior to installing or connecting an 
electrical appliance.
Extension Cord Wire Gauge Size
Amps
10
20
30
40
50
60
80
100
120
5
20
18
16
14
12
12
10
10
8
10
18
16
14
12
12
10
10
8
8
15
16
14
12
12
10
10
8
8
6
20
14
12
12
10
10
8
8
6
6
25
12
12
10
10
8
8
6
6
6
30
12
10
10
8
8
6
6
6
6
35
10
10
8
8
6
6
6
6
6
40
10
8
8
6
6
6
-
-
-
45
8
8
6
6
6
-
-
-
-
50
8
6
6
6
-
-
-
-
-
Length of Extension Cord (ft)