FIG. 37 LIMIT THERMOSTAT TERMINALS
P1800
LIMIT THERMOSTAT (all Models)
FIG. 36 LIMIT THERMOSTAT
Location:
 
The limit thermostat is located in the center of the 
tank lid.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect both black wires from the limit thermo-
stat.
3.  Check for continuity across the limit thermostat 
terminals.
SERVICE (cont.)
If continuity is present as described, the limit thermostat 
is operating properly.
If continuity is not present as described, replace the 
limit thermostat.
Removal and Replacement:
1.  Remove all wires from the limit thermostat termi-
nals.
2.  Carefully slide the limit thermostat out from under 
the retaining clip and remove the limit thermo-
stat.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to schematic wiring diagrams when recon-
necting the wires.
P4102.40
FMD DBC-3 shown
42672 122209