Bunn Beverage Dispenser FMD-5 User Manual

Page of 71
44
SERVICE (cont.)
OVERFLOW PROTECTION SWITCH (FMD-3,DBC-3-4,-5)
FIG. 39 OVERFLOW PROTECTION
SWITCH LEADS
P1212
FIG. 38 OVERFLOW PROTECTION SWITCH
Location:
 
The overflow protection switch is located inside the 
copper overflow cup on the left side of the tank.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Remove the wire nuts connecting the red wires 
from the overflow protection switch to the black 
wire  and blue wire from the main harness.
3.  Check for continuity across the safety overflow 
switch red wires only until the plastic float is raised 
and check that continuity returns when the plastic 
float is again lowered.
If continuity is present as described, reconnect the 
red wires to the black wire  and the blue wire from the 
main harness.
If continuity is not present as described, replace the 
overflow protection switch.
Removal and Replacement:
1.  Disconnect the red leads from the overflow protec-
tion switch from the black wire and the blue wire 
from the main harness.
2.  Remove the nut beneath the copper overflow 
cup.
3.  Remove the entire switch assembly from the cup.
4.  Place the new switch assembly into the cup, wires 
first. Make sure that a gasket is in place around the 
threaded switch stem.
NOTE - The magnets must be at the top of float and 
there must be NO adjusting washers installed for the 
overflow protection switch to operate properly.
5.  Install the nut beneath the copper overflow cup. Be 
sure not to overtighten.
6.  Refer to schematic wiring diagrams when recon-
necting wires.
P4102.40
FMD DBC-3 shown
42672 122209