CALIBRATE FLOW (cont.)
Procedures to calibrate the bypass flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, below 
the funnel on the brewer.
2.  Press and hold the ® pad until the display reads 
SET NEW RECIPES. Release the ® pad. Press and 
release the ® pad until the display reads CALIBRATE 
FLOW.
3.  Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release NO to advance to the BYPASS 
CALIBRATION screen.
5.  Press and release the YES pad. The display should 
read  CONTAINER READY? If the container is 
under the funnel, press YES. The display should 
read  CALIBRATE BYPASS .. PRESS BREW TO 
START.
6.  Press and release the 
 pad. The display should 
read CALIBRATE BYPASS .. 60 SEC TO FINISH. The 
60 second timer on the display will count down to 
zero. When the counter reaches zero, the display 
will change to ENTER OZ., along with a number 
measured in ounces per minute.
7.  Measure the amount of water in the container, and 
using (-) or (+), adjust the amount on the display 
to match the amount in the container. Then press 
DONE.
8.  The display should now read NEW BYPASS FLOW
along with the correct flow rate of the bypass in 
ounces per minute. After about 5 seconds, the dis-
play will return to the CALIBRATE FLOW screen.
9.  To exit the CALIBRATE FLOW function, press and 
release NO to advance to the next function screen, 
or press the 
 pad located on the front switch 
panel to exit the CALIBRATE FLOW function and 
return to the MAIN SCREEN.
ENTER  OZ   XX.X
(-)      DONE       (+)
NEW BYPAS FLOW
XX.X OZ/M
EXIT TO THE
NEXT FUNCTION
SCREEN
COUNTS DOWN
TO ZERO
BREW PRESSED
AFTER 1 MINUTE
CALIBRATE FLOW?
NO                     YES
CONTAINER RDY?
NO                     YES
CALIBRATE BYPASS
PRESS BREW START
CALIBRATE BYPASS
60 SEC TO FINISH
BYPASS CAL?
NO                     YES
SPRAYHEAD CAL?
NO                     YES
P2314
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
34025  022509