Bunn Single SH DBC* (with Smart Funnel) Owner's Manual

Page of 50
Page 28
BYPASS OZ/M:  XX.X
(-)         DONE         (+)
Procedure to adjust the flow rate setting:
1.  Press and hold the ® pad until the display reads SET 
NEW RECIPES. Release the ®. Press and release 
the ® pad until the display reads BYPASS OZ/M
The number represents what the brewer thinks 
is the flow rate of the bypass valve in ounces per 
minute.
2.  If the actual flow rate of the bypass valve is known, 
but is different than the number on the display, use 
the (-) and (+) pads to enter the correct flow rate 
in ounces per minute.
3.  When finished,  press and release the DONE  pad.   
This saves the new setting and advances to the 
next function screen, CALIBRATE FLOW. Another 
alternative is to press the 
 pad located on the 
front switch panel to exit the BYPASS OZ/M func-
tion and return to the MAIN SCREEN.
P2306
XXX    REFILL     XXX
(-)         DONE         (+)
SPRAY OZ/M:  XX.X
(-)         DONE         (+)
Procedure to set the sensitivity threshold of the 
refill circuit:
NOTE: Make sure the water in the tank is touching 
the refill probe.
1.  Press and hold the ® until the display reads SET 
NEW RECIPES. Release the ®.  Press and release 
the ® pad until the display reads REFILL and shows 
a number on both sides of the word.
2.  To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right 
is larger than the number on the left when water is in 
contact with the refill probe in the tank.
3.  When finished, press and release DONE. This 
saves the new setting and advances to the next 
function screen, SPRAY OZ/M. Another alterna-
tive is to press the  
 pad located on the front 
switch panel to exit REFILL and return to the MAIN 
SCREEN.
SPRAY OZ/M
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the sprayhead. This 
is NOT used to change the actual flow rate, but to tell 
the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute. (Oz/M)
Procedure to adjust the flow rate setting:
1.  Press and hold the ® pad until the display reads 
P2304
P2305
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
REFILL - Range: 20 to 230
  This function allows the operator to adjust the 
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting 
the sensitivity of the refill circuit, this will allow the 
brewer to operate under various water conditions.
SET NEW RECIPES. Release the ®.  Press and 
release the ® pad until the display reads SPRAY 
OZ/M. The number represents what the brewer 
thinks is the flow rate of the sprayhead valve in 
ounces per minute.
2.  If the actual flow rate of the sprayhead valve is 
known, but is different than the number on the 
display, use the (-) and (+) pads to enter the cor-
rect flow rate in ounces per minute.
3.  When finished, press and release DONE.  This saves 
the new setting and advances to the next function 
screen, BYPASS OZ/M. Another alternative is to 
press the   
 pad located on the switch panel to 
exit SPRAY OZ/M function and return to the MAIN 
SCREEN.
BYPASS OZ/M
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the bypass nozzle.  
This is NOT used to change the actual flow rate, but to 
tell the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute.
34025  022509