PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
SERVICE TOOLS (cont.)
Testing individual components (outputs):
  This will allow the operator to test the operation 
of individual components and outputs of the brewer.  
The components that can be individually tested are as 
follows:
Brew Valve
Bypass Valve
Funnel Lock (Optional)
Server
Refill Valve
Tank Heaters
Procedure to test components (outputs):
1.  Place brew funnels into rails on the brewer.
2.  Place a Soft Heat
®
 server beneath the brew fun-
nel.
3.  Press and hold the ® pad until the display reads 
SET NEW RECIPES. Release the ® pad. Continue 
pressing and releasing the pad until SERVICE 
TOOLS appears. 
4. Press YES to run tests on various components 
and outputs within the brewer. Pressing NO will 
exit this function and advance to the next function 
screen.
5.  The display should read TEST OUTPUTS.
6.  Press and release YES. The display should read 
BREW VALVE.
7.  To test BREW VALVE, press ON. If the brew valve 
is functional, water should run from the brewer.
8. Press OFF to end flow of water.
9. Press NEXT to advance to the next component to 
be tested.
NOTE: To bypass testing any component, press NEXT 
to advance to the next one, without testing the previ-
ous component.
10. To test BREW BYPASS, press ON. If the bypass 
valve is functional, water should run from the  brew 
bypass.
11. Press OFF to end flow of water.
12. Press NEXT to advance to the next component to 
be tested.
13. To test FUNNEL LOCK, press ON. If the funnel lock 
is functional, the lock will come down to hold the 
funnel in place.
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to 
be tested.
16. To test SERVER, press ON. If the server and the 
sensor are functional, the light on the lower right 
corner of the server will illuminate.
17. Press OFF to end testing of server.
18. Press NEXT to advance to the next component to 
be tested.
19. To test REFILL VALVE, press ON. If the refill valve 
is functional, the sound of the valve operating will 
be heard.
20. Press OFF to end testing of refill valve.
21. Press NEXT to advance to the next component to 
be tested.
22. To test TANK HEATER, connect a voltmeter to the 
tank heater to check for voltage.
23. Press ON. The correct voltage should be present 
at the heater terminals.
24. Press OFF to end testing of the tank heaters.
NOTE: The tank heater will automatically turn off if 
left on too long.
25.  After testing the tank heater, press NEXT to advance 
to the next test.
26. The SPARE TRIAC is reserved for future use.
27. Press NEXT to return to TEST OUTPUTS.
28.  To exit SERVICE TOOLS, press the 
 pad located 
on the front switch panel. This will return to the 
MAIN SCREEN.
Procedure to test switches:
 
This function allows the operator to test the opera-
tion of the individual switches on the front panel.
1.  Place brew funnel into rails on the brewer.
2.  Place a Soft Heat
®
 server beneath the brew fun-
nel.
3.  Press and hold the ® pad until the display reads 
SET NEW RECIPES. Release the ® pad. Continue 
pressing and releasing the ® pad until SERVICE 
TOOLS appears. 
4. Press YES to run tests on various components 
and outputs within the brewer. (Pressing NO will 
exit this function and advance to the next function 
screen.) 