Bunn Single SH DBC* (with Smart Funnel) Owner's Manual

Page of 50
Page 44
34025  022509
TROUBLESHOOTING (cont.)
Problem
Possible Cause
Troubleshooting Procedures
3. Electronic control board
1. Strainer/flow control (.750 GPM)
2. Improper water pressure
3. Brew Valve
4. Bypass Valve
5. Lime buildup
Perform the above procedure for 
testing triacs. If the voltage mea-
sured is very low or zero, then 
substitute a control board known to 
be in good working order.
(A) Direction of flow arrow must be 
pointing towards the brewer.
(B) Remove the strainer/flow control 
and check for obstructions. Clear or 
replace.
Check operating water pressure to 
the brewer. It must be between 20 
and 90 psi (138 and 620 kPa).
Test the Brew Valve. Refer to Testing 
Individual Components on page 33. 
Turn the valve on for 30 seconds and 
collect the water dispensed from the 
sprayhead. Repeat the test several 
times to confirm a consistent volume 
of dispensed water. If not consistent, 
check the valve, tubing and spray-
head for lime buildup.
If bypass is being used on the 
inconsistent brewing recipe, test 
the Bypass Valve. Refer to Testing 
Individual Components on page 33. 
Turn the valve on for 30 seconds 
and collect the water collected 
from the bypass opening. Repeat 
the test several times to confirm 
a consistent volume of dispensed 
water. If not consistent, check the 
valve, tubing and bypass opening 
for lime buildup.
Inspect for lime buildup that could 
block the tank, tank fittings, tubing, 
valves and sprayhead.
Spitting or unusual steaming from 
sprayhead or air vents. (Water too 
hot) (cont.)
Inconsistent beverage level in 
server.