Bunn Single SH DBC* (with Smart Funnel) Owner's Manual

Page of 50
Page 45
34025  012004
TROUBLESHOOTING (cont.)
Problem
Possible Cause
Troubleshooting Procedures
Adjust the brew volume  as required 
to achieve the recommended volume 
for each brew cycle.
Repair or replace leaky valve.
BUNN  paper filters should be used 
for proper extraction.
Check sprayhead
The brew cycle should be started 
only with an empty server under 
the funnel.
Adjust the brew volume as required 
to achieve the recommended volume 
for each brew cycle.
BUNN paper filters should be used 
for proper extraction.
A sufficient quantity of fresh drip 
or regular grind should be used for 
proper extraction.
A clean sprayhead should be used 
to properly wet the bed of ground 
coffee in the funnel.
The BUNN paper filter should be 
centered in the funnel and the bed 
of ground coffee leveled by gentle 
shaking.
Empty the server, remove its cover, 
and place the server beneath the 
sprayhead. Place empty funnel over 
the server entrance, with ON/OFF 
switch in the "ON" position press 
the start switch and release it. Check 
the water temperature immediately 
below the sprayhead with a ther-
mometer. The reading should not 
be less than 195˚F(91˚C).
1. Brew Volume adjustment
1. Brew Valve
1. Type of paper filters
2. No sprayhead
1. Beverage left in server from previ-
ous brew
2. Brew Volume adjustment
1. Type of paper filters
2. Coffee
3. Sprayhead
4. Funnel Loading
5. Water temperature
Consistently high or low beverage 
level in server.
Dripping from sprayhead.
Water overflows filter.
Beverage overflows server.
Weak beverage.