Bunn OL Owner's Manual

Page of 27
Page 21
SERVICE (cont.)
Relay
FIG. 22 RELAY
P1478
Location:
The relay is located under the top cover or top warmer 
housing, FIG. 22.
Test Procedure:
1.  Disconnect the plug terminal from the relay to the 
main wiring harness. Check the voltage across 
the pins of the black wire (P3) and white wire 
(P2) on the main harness with a voltmeter when 
the On/Off brew station warmer switch is in the 
upper “ON” position.  Connect the brewer to the 
power source.  The indication must be:
 
a) 120 volts ac for two wire 120 volt models and 
three wire 120/240 volt models,
 
b) 200 or 240 volts ac for two wire 200 volt or 
240 volt models,
 
c) 100 volts ac for two wire 100 volt models.
2.  Disconnect the brewer from the power source.
3.  Check the voltage across the pins of the blue wire 
(P1) and white wire (P2) on the main harness 
with a voltmeter when the On/Off brew station 
warmer switch is in the upper “ON” position and 
the  start  switch  is  pressed  to  the  lower  posi-
tion and held. Connect the brewer to the power 
source. The indication must be as described in 
step 1.
4.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect relay plug 
to harness and proceed to #5.
If voltage is not present as described, refer to the Wir-
ing Diagrams and check the brewer wiring harness.
5.  Disconnect the plug terminal from the relay to the 
solenoid jumper wire. Check the voltage across 
the pins of the black wire (P3) and white wire 
(P2) on the relay with a voltmeter when the On/
Off brew station warmer switch is in the upper 
“ON” position.  Connect the brewer to the power 
source.  The indication must be as described in 
step 1.
6.  Disconnect the brewer from the power source.
7.  Check  the  voltage  across  the  pins  of  the  blue 
wire (P1) and white wire (P2) on the relay with a 
voltmeter when the On/Off brew station warmer 
switch is in the upper “ON” position and the start 
switch is pressed to the lower position and re-
leased. Connect the brewer to the power source. 
The indication must be as described in step 1.
8.  Disconnect the brewer from the power source.
If voltage is present as described, the relay is operat-
ing properly.
If  voltage  is  not  present  as  described,  remove  and 
replace the relay.
Removal and Replacement:
1.  Disconnect the brewer from the power source.
2.  Remove the top cover or top warmer housing.
3.  Disconnect both plug terminals from the relay.
4.  Remove  the  two  #8-32  screws  attaching  the 
relay  and  bracket  assembly  to  the  component 
bracket.
5.  Remove the #6-32 screw attaching the relay to 
the bracket.
6.  Securely attach the new relay to the bracket using 
the #6-32 screw.
7.  Attach  the  new  relay  and  bracket  assembly  to 
the  component  bracket  using  the  two  #8-32 
screws.
8.  Reconnect the relay wire terminals to their respec-
tive plugs in the main harness and the jumper 
wire at the solenoid valve.
32430 121699