SERVICE (cont.)
Water Level and Overflow Safety Switch
FIG. 25 WATER LEVEL and OVERFLOW
SAFETY SWITCHES
P1478
Location:
The water level and overflow safety switches are lo-
cated under the top cover or top warmer housing and 
inside and front of the tank fill basin, FIG. 25.
Test Procedure:
1.  Disconnect the brewer from the power source.
2.  Remove the top cover or top warmer housing.
3.  Remove the leads of the switch being tested from 
the connection block mounted on the front of the 
tank basin.
4.  Check the voltage across each black lead of the 
connection block and the white or red lead on 
the solenoid coil with a voltmeter. Turn the ON/
OFF switch to the “ON” position and connect the 
brewer to the power source. The indication must 
be:
 
a) 120 volts ac for two wire 120 volt models and 
three wire 120/240 volt models,
 
b) 200 or 240 volts ac for two wire 200 volt or 
240 volt models,
 
c) 100 volts ac for two wire 100 volt models.
5.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the Wir-
ing Diagrams and check the brewer wiring harness.
6.  Check for continuity across the overflow switch 
pink  wires  only  until  the  plastic  float  is  raised 
and check that continuity returns when the float 
is lowered again.
7.  Check for continuity across the water level switch 
pink wires only until the plastic float is raised and 
check that continuity returns when the float is 
lowered again.
If continuity is present as described, reconnect the 
wires as shown in FIG. 30, the switches are operating 
properly.
If continuity is not present as described, replace the 
failed switch.
Removal and Replacement:
1.  Disconnect the brewer from the power source.
2.  Remove the top cover or top warmer housing.
3.  Remove the wire leads connecting the water level 
and overflow switches to the terminal block at the 
front of the tank and fill basin.
4.  Disconnect  the  #8-32  screw  and  remove  the 
entire  switch  assembly  from  the  tank  and  fill 
basin.
5.  Place the new switch assembly into the bracket, 
wires up.
NOTE- The magnets must be at the top of the float and 
there must be NO adjusting washers installed for the 
overflow safety switch to operate properly.
6.  Install  the  nuts  over  the  wires  and  secure  the 
switch  to  the  mounting  bracket.  Do  not  over 
tighten.
7.  Attach the entire switch assembly to the tank and 
fill basin using the #8-32 screw.
8.  Add or remove washers to the float on the level 
switch as required. Adding washers increases the 
volume, removing washers decreases it.
9.  Refer to FIG. 26 and the relative wiring diagram 
when reconnecting wires.
FIG. 26 WATER LEVEL and OVERFLOW
SAFETY SWITCH WIRING
P1478
to BLK on Start Switch
to BLK on Brew Station 
Warmer Switch
32430 121699