Windsor ENSIGN E50 10070090 User Manual

Page of 26
MAINTENANCE 
 ENSIGN  86038250  02/12/07 
      4-3 
 
Only qualified 
maintenance 
personnel are to 
perform the following repairs
 
 
SOLUTION PUMP REPLACEMENT 
1.  Turn off all switches and unplug the 
machine. 
2.  Remove recovery tank. 
3.  Remove solution hoses from fittings in pump. 
4.  Remove the screws that fasten the pump to 
the frame. 
5.  Reverse process to install pump. 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
Valve Asm 
86258840 
PRV NO. 84162 
Diaphragm 
86255110 
PRV NO. 29207
Pump Head  
86251050 
PRV NO. 65188 
PUMP (86201410 PRV NO. 250-63) REPLACEMENT KIT 
 
Pump Head  
86017350 
PRV NO. 65235 
Valve Asm 
86017370 
PRV NO. 84191 
Diaphragm 
86017390 
PRV NO. 29263 
PUMP (86251160 PRV NO. 65233) REPLACEMENT KIT