Wegener Communications 6420 User Manual

Page of 135
 
 
iPump 6420 User’s Manual
 
www.wegener.com 
800070-01 Rev B 
Chapter 4, Page 102 
4.1. Maintenance 
Maintenance of the iPump 6420 is limited to keeping the chassis clean and ensuring that 
cables remain firmly connected.  Occasionally wipe the exterior with soft, damp cloth to remove 
any accumulated dust and dirt, in order to keep the air vents clear. 
Occasionally monitor the unit’s temperature indication to see that it remains fairly constant 
while in use in a static location.  A sudden increase in the baseline daily temperature, with no 
other explanation, may indicate a failure in an internal ventilation fan.  If the unit temperature 
increases, and this may be attributable to a hotter ambient environment, then it is suggested that 
some effort be made to improve the local cooling.  The iPump 6420 will give a much longer 
operating lifetime if kept cool. 
Occasionally monitor the unit for any Warnings about over-temperature or HDD problems.  
This is especially important if the HDD has seen more than 5 years of operation. 
 
The iPump 6420 incorporates security labels over some of the chassis screws.  There are no 
user-serviceable components within the iPump 6420.  Tampering with security labels or opening 
the unit will void your warranty, unless you are given written permission by WEGENER 
Customer Service 
or some other authorized WEGENER representative
.  If you have any 
questions, contact WEGENER’s Customer Service Department at the street address, email 
address, or phone numbers listed under Customer Service. 
4.2. Troubleshooting 
When the common system problems occur, and they will, it is best to first consult the first 
three chapters of this Manual.  After that, look for your problem in the following subsections and 
then review the checklists given.  Following that, if there is still a problem, call WEGENER 
Customer Service
 for assistance. 
4.2.1. 
Failure to acquire a carrier 
1.  Sure you do not have carrier lock?  Check CARRIER LED. 
2.  Is signal level displayed on Front-panel between 10 and 90?  If only 0, then 
functioning LNB is probably not connected to the i6420, or i6420 internal receiver 
card is failed. 
3.  RF input cable securely attached? 
4.  External LNB powered with DC?  Is LNB DC from unit ON? 
5.  Correct tuning parameters:  Carrier frequency, data-rate, FEC ratio? 
6.  Are carrier ID tags required?  Is carrier tag set correctly in i6420? 
7.  Can other receivers on same antenna lock to this carrier?